Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 6274.015 - Employee crushed beneath a shipping container.

Accident Summary Nr: 6274.015 -- Report ID: 0936200 -- Event Date: 01/19/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
189967.01501/20/2012488320Ssa Marine

Abstract: At 6:45 p.m. on January 19, 2012, at Cosco Japan at the port of Long Beach, CA, Berth J245, Employee #1 was supervising a container crane operator, while aboard a vessel on the cargo hatch in Bay #34. The container crane was offloading 20 ft and 40 ft shipping containers from the hatch cover on loading Bay 34, aboard the vessel. The crane was handling a two stack high 20 ft container in the 3rd row from the offshore side. The spreader cables dislodged an adjacent six stack high, 40 ft container from the 2nd row of the offshore side. The 40 ft container fell, landing on a 20 ft container below on the hatch cover and then tumbled into the bay, crushing Employee #1 beneath the shipping container. The 40 ft long shipping container was reported to weigh 8.8 tons.

Keywords: Accidental Discharge, Containerized Cargo, Crane, Crushing, Falling Object, Longshoring, Material Handling, Ship, Struck By, Suspended Load

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 189967.015 47 M Fatality Longshore equipment operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.