Accident Summary Nr: 607416 - TRUCK CRANE BOOM COLLAPSED, CAUSING NO INJURIES

Accident Summary Nr: 607416 -- Report ID: 0418100 -- Event Date: 12/31/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10126447112/31/198717710Metromont Materials Corp.

Abstract: A 140 TON LINK-BELT FMC 238A TRUCK CRANE WAS BEING USED TO LIFT THE CENTER COLUMN OF A PARKING GARAGE UNDER CONSTRUCTION. THE COLUMN WAS 72 FEET LONG AND WEIGHED 60,900 POUNDS. TWO LINES WERE BEING USED; ONE WAS RIGGED TO A LARGE LIFTING LOOP AT THE TOP OF THE COLUMN AND THE SECOND WAS RIGGED TO THE THIRD AND FIFTH EMBEDDED SIDE LIFTING LOOPS. THE COLUMN HAD BEEN LIFTED AND WAS BEING "ROLLED" FROM A HORIZONTAL TO A VERTICAL POSITION WHEN THE FIFTH LIFTING LOOP BROKE OFF, CAUSING THE COLUMN, ALONG WITH THE 150 FOOT CRANE BOOM, TO FALL INTO A DOWNTOWN INTERSECTION. THERE WERE NO INJURIES. THE LIFTING LOOP WHICH BROKE DID NOT HAVE A SAFETY FACTOR OF AT LEAST 5 TIMES THE WORKING LOAD, AS REQUIRED BY ANSI A 10.9 - 1970, SECTION 9.8, OR SAFETY FACTOR OF 4 AS REQUIRED BY ANSI A10,9 - 1983, SECTION 9.3.3. THERE WAS SIGNIFICANT PUBLICITY AND PROPERTY DAMAGE FROM THIS ACCIDENT. THE CONCRETE COLUMN HAD BEEN MANUFACTURED AT THE COMPANY'S PRESTRESS CONCRETE PLANT.

Keywords: COLLAPSE, CRANE BOOM, TRUCK CRANE, CONSTRUCTION, CRANE, UNSTABLE LOAD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 101264471

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close