Accident Summary Nr: 606194 - Employee killed when crushed by overturned loader

Accident Summary Nr: 606194 -- Report ID: 0418100 -- Event Date: 09/08/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
119908209/08/198616290Jellico Realty Co.

Abstract: Employee #1 was operating a 1964 Caterpillar loader, serial #53A5348, alongside the edge of a 38 ft high hill that he was cutting down when the loader slid partially downhill and flipped over, crushing and killing him. The loader had a bush guard that collapsed at all four posts. It was not equipped with a roll-over protective structure or seat belts.

Keywords: GUARD, ROPS, CONSTRUCTION, CRUSHED, SEAT BELT, LOADER, LOST CONTROL, SLOPE, OVERTURN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1199082 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.