Accident Summary Nr: 605576 - Employee's pelvis fractured in trench cave-in

Accident Summary Nr: 605576 -- Report ID: 0418100 -- Event Date: 05/28/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10109876205/28/198616230Billy Gerrell Grading Inc.

Abstract: Employee #1 was in a 19 to 21 ft deep and 31 feet wide sewer line trench. The sides of the trench were slightly sloped. Employee #1 was aligning the laser and clearing dirt from the end of an 8 in. ductile sewer pipe. He was on his knees when a slick head kicked out of the side of the trench and he was completely buried. He was removed from the trench within 25 minutes. Employee #1 was hospitalized with a pelvis fracture in three places. The excavated dirt was piled high at the edge of the trench opposite the side that caved in. No ladder was available and hard hats were worn. Sloping was inadequate and no shoring or trench box was used. Employees were not adequately trained. The foreman was nearby in a manhole; a coworker was on the bank.

Keywords: FRACTURE, TRENCH BOX, WORK RULES, CONSTRUCTION, TRENCH, SHORING, SLOPING, BURIED, CAVE-IN, UNTRAINED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101098762 Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close