Accident Summary Nr: 603381 - One employee killed, one injured in fall from falling beam

Accident Summary Nr: 603381 -- Report ID: 0419400 -- Event Date: 10/15/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
168346510/19/199217910Fischer Steel Corporation

Abstract: A crew was erecting structural steel. Several 32 ft tall columns had been erected and bolted down to the footing with two anchor bolts. A 70 ft bridge beam had just been secured to the top of two columns and the two chockers were removed from the lifting crane by Employee #1 and a coworker, both connectors. The beam and columns began to fall away from the crane. The coworker made it safely to one of the columns. As he slid down it, he was thrown off to the concrete floor and fractured his hip. Apparently, Employee #1 tried to ride the beam down; however, the beam flipped upside down and threw him to the floor. He sustained a concussion and was killed. Two anchor bolts had pulled out of the concrete footing of one of the columns. These two anchor bolts had been damaged but had been replaced several days earlier.

Keywords: ERECTION PROCESS, FRACTURE, STEEL BEAM, CONSTRUCTION, EQUIPMENT FAILURE, STEEL ERECTION, BOLT, FALL, CONCUSSION, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1683465 Fatality Concussion Occupation not reported
2 1683465 Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close