Accident Report Detail

Accident Summary Nr: 602904 - Employee killed in fall with radio tower

Accident Summary Nr: 602904 -- Report ID: 0418300 -- Event Date: 07/23/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
10895552709/08/199217950Sharp Communications, Inc.

Abstract: Employees were dismantling a 190 ft AM radio tower. The tower had been dismantled down to the last 30 ft and the last set of permanent guy wires. Employee #1, with the help of two groundspeople, attached three temporary guy wires of 5/8 in. hemp rope. The tower was a Rohn 25 G, mounted on a Racal-Decca Canada, Inc., A4101 base. After Employee #1 had installed the temporary guys, a coworker mounted the tower at the 20 ft level with Employee #1 at the 30 ft level. When the permanent guys were removed, the tower fell. The employees were belted to the tower and fell with it. Employee #1 was killed when he fell on a support strap around the tower, which punctured his stomach and chest.

Keywords: CHEST, COMMUNICATION TOWER, DISMANTLING, ROPE, UNSECURED, CONSTRUCTION, GUY, FALL, STOMACH, PUNCTURE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 108955527 Fatality Puncture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close