Accident Summary Nr: 601997 - MAINTENANCE WORKER KILLED BY FALLING CONCRETE PANEL

Accident Summary Nr: 601997 -- Report ID: 0420600 -- Event Date: 03/06/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10296001003/07/198915410Trac Design Builders, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
1824136403/07/198965520Thompson-Rubin Associates

Abstract: A maintenance worker from a nearby office industrial building was crushed while making a telephone call from a construction trailer parked adjacent to a building under construction in an industrial park when an inadequately braced precast concrete panel weighing in excess of 36,000 pounds collapsed onto the trailer. Investigation revealed both braces on the panel were inadequately installed. One was improperly pinned so that it had no tensile strength, while the other had an improperly torqued expansion bolt at its bottom anchorage. A gust of wind likely blew the panel over.

Keywords: FRACTURE, HIGH WIND, MAINTENANCE, CONCRETE PANEL, TORSO, CRUSHED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 102960010 Occupation Not Listed
2 18241364 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close