Accident Summary Nr: 599597 - Employees killed in fire and explosion in spray booth

Accident Summary Nr: 599597 -- Report ID: 0420300 -- Event Date: 07/19/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
10946741507/20/199597110U.S. Dept. Of Army
Inspection NrDate OpenedSICNAICSEstablishment Name
10946737307/20/199597110U.S. Dept. Of Army

Abstract: On July 19, 1995, Employees #1 and #2, painters, were applying 791 peelable booth coating, a class 1B flammable liquid, with an airless sprayer inside a large paint spray booth. The paint sprayer was not explosion-proof and was not approved to be used in this location. All the doors to the spray booth were closed and the ventilation system was not turned on. One of the employees was operating the spray gun while the other employee helped. After approximately 45 to 60 minutes, an explosion and fire occurred inside the booth, killing Employees #1 and #2.

Keywords: BURN, VENTILATION, FLAMMABLE LIQUID, WORK RULES, FIRE, SPRAY PAINTING, EXPLOSION, PAINTER, SPRAY BOOTH

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 109467415 Fatality Burn/Scald(Heat) Occupation not reported
2 109467415 Fatality Burn/Scald(Heat) Occupation not reported
3 109467373 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.