Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 597518 - Employee's leg crushed by scissor lift

Accident Summary Nr: 597518 -- Report ID: 0418100 -- Event Date: 04/01/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
11011122604/01/199235240Snapper, Inc.

Abstract: Employee #1 responded to a second maintenance call on a hydraulic scissor lift that was installed into a floor pit. He determined that a leak in a hydraulic hose was causing the problem and attempted to remove and replace the defective hose. During removal of the defective hose, hydraulic pressure was released and the scissor lift fell to its down position. Employee #1's left leg was crushed and the bones were fractured.

Keywords: LEAK, FRACTURE, HYDRAULIC LIFT, MAINTENANCE, HOSE, HYDRAULIC LINE, CRUSHED, FALL, FALLING OBJECT, LEG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 110111226 Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.