Accident Summary Nr: 597229 - Employee dies in fall inside water tank

Accident Summary Nr: 597229 -- Report ID: 0418100 -- Event Date: 03/25/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11006920003/27/199117990B & B Blasting & Coating

Abstract: At approximately 2:00 p.m. on March 25, 1991, Employee #1 was sandblasting inside a 122 ft high water tank when the cable holding the scaffolding apparently slipped. The employee fell approximately 70 ft to his death. He was wearing a safety belt but the lifeline broke.

Keywords: LIFELINE, WIRE ROPE, SLIP, CONSTRUCTION, EQUIPMENT FAILURE, FALL, SANDBLASTING, WATER TANK, SCAFFOLD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 110069200 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.