Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 595025 - Employee killed when crushed by falling metal baskets

Accident Summary Nr: 595025 -- Report ID: 0420100 -- Event Date: 09/22/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
10696515509/27/199544910Cooper T. Smith Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10696520509/27/199544910Copestone Services Corp
Inspection NrDate OpenedSICNAICSEstablishment Name
1739770409/27/199544910Lash Intermodal Terminal Company

Abstract: A four-man work crew including Employee #1 was unloading metal baskets filled with crude rubber from a barge. The baskets were stacked three high and lifted two rows at a time. The gear used to accomplish the lift was a 60 in. by 24 in. rectangular rubber spreader with a 5 ft long wire rope attached at each corner. At the opposite end, the wire ropes were attached by a shackle to two 8 ft long wire ropes, each fitted with a steel J-hook. One employee operated the bridge crane while another positioned the baskets for unloading with a forklift. The two remaining employees attached the J-hooks of the special stevedoring gear to the baskets for unloading. The hooks were attached to the load by hooking them to the rim along the top of the bottom basket of the stack. The gear was certified for the load, but because of the bent and sprung condition of the J-hooks, after the load was lifted approximately 1 to 2 in. from the ground, one of the hooks slipped. The three baskets being lifted on that side of the gear became unstable and they all fell. The top basket fell onto Employee #1 and crushed him to death.

Keywords: LONGSHORING, HOISTING MECHANISM, INADEQUATE MAINT, SLIP, CRUSHED, OFF LOADING, STRUCK BY, FALLING OBJECT, UNSTABLE LOAD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 106965155 Occupation Not Listed
2 106965205 Fatality Fracture Occupation not reported
3 17397704 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.