Accident Summary Nr: 593558 - ELECTRIC SHOCK - GROUND FAULT IN CHOP SAW CONTROL

Accident Summary Nr: 593558 -- Report ID: 0419400 -- Event Date: 09/09/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
10267911509/09/199424480Alford Lumber Company, Inc.

Abstract: An industrial truck operator filling in for an absent chop saw operator was running a chop saw from a remote station. It had rained the previous night, and accumulated saw dust was saturated with water. A foot treadle in the operating station had come loose from its mount and had fallen into the saturated saw dust. The employee apparently stepped into the sawdust, which had been energized by the broken control. He was electrocuted. (There were no witnesses to the accident.)

Keywords: E GI V, ELECTRICAL, ELECTROCUTED, GROUND FAULT, ELEC CIRC PART--MISC, ELEC EQUIPMENT--MISC, WATER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 102679115 Fatality Electric Shock Industrial truck and tractor equipment operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.