Accident Summary Nr: 58389.015 - Employee, crushed by elevator, is killed

Accident Summary Nr: 58389.015 -- Report ID: 0419400 -- Event Date: 02/21/2014
Inspection NrDate OpenedSICNAICSEstablishment Name
959928.01502/22/2014238290Midsouth Elevator, Llc

Abstract: At 5:15 p.m. on February 21, 2014, an employee was dispatched to a hotel to repair a malfunctioning elevator. The employee was working alone inside an elevator shaft trying to troubleshoot the elevator. The elevator was somehow activated and rose to the top floor with the employee working on top of it. The employee was pinned between the top of the elevator and the overhead concrete ceiling. He received trauma to the chest and was killed

Keywords: Crushing, Elevator, Elevator Shaft, Lockout, Lockout/Tagout, Repair

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 959928.015 24 M Fatality Elevator installers and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.