Accident Summary Nr: 571745 - CAUGHT IN CONVEYOR DRUM AT AN INGOING NIP POINT

Accident Summary Nr: 571745 -- Report ID: 0521100 -- Event Date: 08/26/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
242360608/26/198532730Green And Gold Concrete Co

Abstract: EMPLOYEE #1 CAUGHT HIS ARM IN A NIP POINT BETWEEN THE BELT AND THE DRIVING DRUM AT THE DISCHARGE END OF A CONCRETE AGGREGATE CONVEYOR. EMPLOYEE #1 WAS PULLED HEAD FIRST OVER THE BELT AND DRUM AND WAS PINNED HEAD DOWN IN A HOPPER WITH HIS CHEST AGAINST THE BELT AND THE DRUM. HIS ARM WAS WEDGED BETWEEN THE UNDERSIDE OF THE DRUM SHAFT AND THE PILLOW BLOCK. THE CAUSE OF DEATH WAS ASPHYXIATION DUE TO BROKEN RIBS BEING COMPRESSED AGAINST THE LUNGS. FACTORS WHICH CONTRIBUTED TO THE DEATH WERE AN UNGUARDED INGOING NIP POINT AND AN EMERGENCY STOP CORD THAT ENDED APPROXIMATELY 6 FEET FROM THE THE NIP POINT.

Keywords: CHEST, ASPHYXIATED, DRUM, EMERGENCY STOP, CAUGHT BETWEEN, ARM, NIP POINT, CONVEYOR BELT, UNGUARDED, HOPPER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2423606 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close