Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 570184 - Employee killed when crushed by roller compactor

Accident Summary Nr: 570184 -- Report ID: 0521700 -- Event Date: 07/02/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
248198407/03/198516110Bongi Cartage Inc

Abstract: Employee #1 was operating a rider roller compactor when he fell from the operator's seat. He caught himself by grabbing onto the control, which then threw the roller into full reverse, dragging him across a busy highway and striking a curb, where he lost his grip and fell. Employee #1 was completely crushed and killed by the roller.

Keywords: HIGHWAY, ROLLER--CONST EQUIP, CONTROL LEVER, EQUIPMENT OPERATOR, STRUCK AGAINST, CONSTRUCTION, DRAGGED, CRUSHED, FALL, UNMANNED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2481984 Fatality Other Paving, surfacing and tamping equipment operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.