Accident Summary Nr: 566612 - Employee dies from inhalation of hazardous gas in frac tank

Accident Summary Nr: 566612 -- Report ID: 0636900 -- Event Date: 11/05/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
11037053311/09/1993138903-R Services, Inc.

Abstract: At approximately 10:45 p.m. on November 5, 1993, Employee #1 was on top of a frac tank that was being used to recover the backflow from an oil well. Employee #1 was measuring the fluid level of the frac tank using a tank gauge. The backflow from the oil well consisted of water, compressed nitrogen gas, and a little sand. Employee #1 was using a flashlight to peer into an opening that was approximately 2 ft by 2 ft. A coworker was assisting Employee #1 by opening the flow line at the oil well. Employee #1 apparently dropped the flashlight into the opening and climbed into the frac tank to retrieve it. The coworker, who was approximately 65 ft away, went over to the tank to see why Employee #1 was not on top of the tank. Employee #1 had been overcome by the gas in the frac tank. The coworker attempted to rescue Employee #1 from the frac tank but was not successful. Employee #1 died.

Keywords: OXYGEN DEFICIENCY, CONFINED SPACE, WORK RULES, FRAC TANK, INHALATION, GAS, NITROGEN, OIL WELL SERVICING, OVEREXPOSURE, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 110370533 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close