Accident Summary Nr: 565762 - Employee killed by cotton gin rotating shaft

Accident Summary Nr: 565762 -- Report ID: 0636900 -- Event Date: 12/18/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10660787212/20/199007240Olney Gin, Division Of Co-Ag

Abstract: On or about December 18, 1990, approximately six employees were engaged in cotton ginning operations. The rain-soaked cotton clogged some of the equipment, causing a shutdown in order to clear the obstruction. If cotton is wet or damp, clogging happens approximately 3 to 4 times on average per shift. At approximately 11:00 a.m., the Steady Flow machine became clogged. The ginner shut down all the equipment and the employees began taking the cotton out of the Steady Flow, throwing it on the floor between the Steady Flow and the Little David machine. After all the cotton had been removed, the employees prepared to pick the cotton off the floor and place it in a bag used in baling. The bag measures approximately 3 ft deep by 26 in. wide by 60 in. long and is usually held open by two employees while two or three others place the cotton inside. Employee #1 placed himself inside the bag, holding one end open, and while scooping up the cotton, he was stepping or hopping backward. The ginner turned on the machinery and, when he returned to the baling area, he saw Employee #1 had become entangled in an unguarded rotating shaft, apparently because the bag became entangled. Although the ginner ran for the disconnect switch, Employee #1 died. The switch was located some distance away and was obstructed from view.

Keywords: ROTATING SHAFT, AGRICULTURE, WORK RULES, CAUGHT BY, COTTON GIN, ENTANGLED, WALKING BACKWARD, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 106607872 Fatality Fracture Supervisors; handlers,equip-cleaners,laborers nec

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close