Accident Report Detail

Accident Summary Nr: 565689 - ELECTRIC SHOCK - GROUND FAULT IN ELECTRIC FURNACE

Accident Summary Nr: 565689 -- Report ID: 0636900 -- Event Date: 08/28/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10149149608/29/198933980Hinderliter Heat Treating, Inc.

Abstract: A PRESSURE VESSEL WAS BEING TREATED IN AN ELECTRIC HEAT-TREATING FURNACE. THE VESSEL WAS PLACED IN THE FURNACE, WITH A SHORT PIECE OF PIPING WITHIN 0.5 INCHES OF THE RESISTIVE HEATING ELEMENT. AS THE TEMPERATURE ROSE IN THE FURNACE, THE 480-VOLT ELEMENT EXPANDED AND CONTACTED THE PRESSURE VESSEL. SINCE IT WAS ISOLATED FROM GROUND, THE VESSEL BECAME ENERGIZED. A THERMOCOUPLE, WHICH WAS ATTACHED TO THE PRESSURE VESSEL, WAS CONNECTED TO A TEMPERATURE RECORDING INSTRUMENT. THE THERMOCOUPLE, HAVING ALSO BECOME ENERGIZED THROUGH CONTACT WITH THE PRESSURE VESSEL, CAUSED THE RECORDING INSTRUMENT TO MALFUNCTION. AN EMPLOYEE WAS CALLED IN TO TROUBLESHOOT THE RECORDER MALFUNCTION. THE THERMOCOUPLE WIRES WERE DISCONNECTED FROM THE RECORDER, AND A CHECK WAS MADE OF THE INSTRUMENT. WHEN THE EMPLOYEE PICKED UP THE EXPOSED THERMOCOUPLE WIRES SO THAT HE COULD RECONNECT THEM, HE WAS IN CONTACT WITH A GROUNDED SURFACE. THE EMPLOYEE WAS ELECTROCUTED.

Keywords: E GI III, ELECTRICAL, ELECTROCUTED, ELECTRONIC EQUIPMENT, TEST EQUIPMENT, GROUND FAULT, ELEC EQUIPMENT--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101491496 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close