Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 565507 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Accident Summary Nr: 565507 -- Report ID: 0627100 -- Event Date: 10/20/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
10770315910/28/199232710Ark-Crete Block Co., Inc.

Abstract: AN EMPLOYEE WAS USING A BOOM TRUCK TO LOAD A PALLET OF CONCRETE BLOCKS BACK ONTO A TRAILER AT A JOBSITE. HE WAS STANDING ON THE GROUND, OPERATING THE BOOM WITH A REMOTE CONTROL UNIT. THE BOOM CONTACTED AN 8000-VOLT OVERHEAD POWER LINE, AND THE EMPLOYEE WAS ELECTROCUTED.

Keywords: BOOM TRUCK, OVERHEAD POWER LINE, ELECTRICAL, BOOM, ELECTROCUTED, E GI IA, TRUCK BOOM

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107703159 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.