Accident Summary Nr: 565127 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Accident Summary Nr: 565127 -- Report ID: 0627100 -- Event Date: 05/12/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
10770675605/13/199202510George'S Farms, Inc.

Abstract: A FEED TRUCK DRIVER HAD PARKED HIS TRUCK BENEATH AN OVERHEAD POWER LINE AND HAD FILLED A FEED BIN. THE BIN WAS LOCATED 19 FEET, 5 INCHES ABOVE THE GROUND, AND THE POWER LINE WAS LOCATED 23 FEET, 8.5 INCHES ABOVE THE GROUND. THE TRUCK DRIVER, WHO WAS OPERATING THE BOOM FROM THE CONTROL STATION AT THE LEFT REAR OF THE TRUCK, RAISED THE BOOM WHEN HE WAS FINISHED FILLING THE BIN. THE BOOM CONTACTED THE POWER LINE, ELECTROCUTING THE EMPLOYEE. INVESTIGATION REVEALED THAT THE SUN MAY HAVE IMPAIRED THE EMPLOYEE'S VIEW AS HE WAS POSITIONING THE BOOM.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, SCREW CONVEYOR, ELECTROCUTED, E GI IA

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107706756 Fatality Electric Shock Truck drivers, heavy

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.