Accident Report Detail
Accident Summary Nr: 556530 - EMPLOYEES INJURED WHEN EXPOSED TO TOXIC VAPORS
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 108768961 | 12/04/1991 | 3443 | 0 | Long Reach Manufacturing, Co. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 108768953 | 12/04/1991 | 2992 | 0 | Cetel Processing, Inc. |
Abstract: A COMPANY UNIT WAS REPROCESSING RESIDUAL FUEL OIL, A BYPRODUCT OIL MIXTURE. IN THIS PROCESS, THE RESIDUAL FUEL OIL IS REACTED WITH SULFURIC ACID AND WATER TO TAKE SODA ASH AND OTHER IMPURITIES OUT OF THE OIL. A REACTION WAS STARTED IN A 10,000-GALLON PROCESSING TANK. WHEN THE REACTION STARTED, A PROCESS UPSET OCCURRED, CAUSING AN OVERPRESSURIZATION OF THE TANK AND A VAPOR CLOUD RELEASE. THE TOXIC VAPOR CLOUD DRIFTED 500 FEET TO THE SITE OF AN ONGOING INSPECTION AND AFFECTED EMPLOYEES #1 THROUGH #17 WHO WERE TAKEN TO THE HOSPITAL AFTER SUFFERING HEADACHES, NAUSEA, AND BURNING EYES. EMPLOYEES #1 THROUGH #17 WERE RELEASED THAT AFTERNOON AFTER TREATMENT AND OBSERVATION.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 2 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 3 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 4 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 5 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 6 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 7 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 8 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 9 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 10 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 11 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 12 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 13 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 14 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 15 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 16 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 17 | 108768961 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 18 | 108768953 | Occupation Not Listed |
Translate