Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 525592 - EMPLOYEE IMPALED IN HEAD BY MACHINE PART

Accident Summary Nr: 525592 -- Report ID: 0830600 -- Event Date: 12/06/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
10057599212/09/199132640Coors Ceramic Company

Abstract: EMPLOYEE #1, AN EQUIPMENT SETUP MAN, WAS FABRICATING A CERAMIC PULLEY ON A COMPUTER NUMERIC-CONTROL LATHE, HITACHI SEIKI HT 20SII, #HTS21617. THE INTERLOCK ON THE SLIDING DOOR OF THE LATHE HAD BEEN DISABLED BY A RUBBER BAND SO THAT IT COULD OPERATE WITH THE PROTECTIVE DOOR OPEN. EMPLOYEE #1 PLACED HIMSELF IN THE PATH OF THE MOVING TURRET AND WAS IMPALED IN THE HEAD, AND KILLED, BY A TOOL ON THE TURRET.

Keywords: HEAD, LATHE, IMPALED, WORK RULES, LOCKOUT, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100575992 Fatality Puncture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.