Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 514927 - Employee burned in fire after heat exchanger ruptures

Accident Summary Nr: 514927 -- Report ID: 0625700 -- Event Date: 11/04/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11041934811/05/199029110Mobil Oil Corporation/Chalmette Refinery
Inspection NrDate OpenedSICNAICSEstablishment Name
11033668211/05/199029110Mobil Oil Corporation/Chalmette Refinery
Inspection NrDate OpenedSICNAICSEstablishment Name
11041926411/07/199017310Orleans Electric & Const. Co., Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
11041924912/04/199029110Delta Maintenance, Inc.

Abstract: At approximately 11:30 p.m. on November 4, 1990, Employee #1, an assistant operator in the hydrocracker unit (HCU) of a refinery, was manually opening a bypass valve to increase the flow rate in the unit. The bypass was being used because the second-stage charge motor control valve was not working properly. As Employee #1 was opening the bypass valve, he heard a "whooshing" sound in the unit, to his west. A heat exchanger, identified as E2314, ruptured on the shell side, releasing vapors that were ignited by the first-stage prefeed heaters. Employee #1 sustained first-, second-, and third-degree burns over 70 percent of his body. The shell side of the exchanger had thinned to 0.1 inch, and failed at the normal operating pressure of 255 psi. The accident investigation revealed no connection between the failure of the heat exchanger shell and the operation of the manual bypass valve.

Keywords: FLAMMABLE VAPORS, WORK RULES, EQUIPMENT FAILURE, EXPLOSION, HEAT EXCHANGER, BURN, HEATER, FIRE, RUPTURE, REFINERY

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 110419348 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 110336682 Occupation Not Listed
3 110419264 Occupation Not Listed
4 110419249 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.