Accident Summary Nr: 514802 - One employee killed, one injured when pipe releases pressure

Accident Summary Nr: 514802 -- Report ID: 0625700 -- Event Date: 03/14/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11034135103/22/199029110Citgo Petroleum Corporation-Lcmc

Abstract: At approximately 11:35 p.m. on March 14, 1990, Employees #1 and #2 were working in the C-cat unit at the Citgo Refinery in Lake Clade, LA. They were standing on an overhead pipe rack cracking a valve on a 10-in.-diameter steam line to allow steam to flow into downstream piping. The pressure in the line was approximately 250 OPR. There was a sudden unexpected rupture in two 10-in.-diameter steam lines approximately 10 ft upstream from where the employees were working. The sudden eruption of steam knocked Employee #1 from the pipe rack 15 ft to the ground. He suffered a head fracture and died on March 20, 1990. Employee #2 was knocked onto the pipe rack, and he sustained shrapnel wounds to his back. The employees were not wearing fall protection.

Keywords: HEAD, STEAM LINE, WORK RULES, RUPTURE, BACK, HIGH PRESSURE, FALL, FALL PROTECTION, PRESSURE RELEASE, REFINERY

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 110341351 Fatality Fracture Occupation not reported
2 110341351 Non Hospitalized injury Cut/Laceration Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close