Accident Summary Nr: 514752 - Employee struck and killed by swinging marine arm

Accident Summary Nr: 514752 -- Report ID: 0625700 -- Event Date: 01/21/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10763003001/22/199016290J. E. Merit Construction, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10763002201/21/199044910Riverside Marine Services
Inspection NrDate OpenedSICNAICSEstablishment Name
10763005501/21/199029110Bp Oil Company
Inspection NrDate OpenedSICNAICSEstablishment Name
10763004801/22/199035330Fmc Corporation

Abstract: On Sunday, January 21, 1990, at approximately 5:10 a.m., Employee #1, a licensed tankerman, was employed by Riverside Marine Services, which was contracted to off load a barge containing isobutane at the BP Oil Refinery (dockside) in Belle Chasse, LA. The barge had been off loaded, and Employee #1 had disconnected the flange on the Chiksan south marine arm, which was the vapor line, from the barge and was storing the arm on the dock. Three Crosby fist grip clips were attached to the 0.625-inch wire rope retaining line. The clips came off the wire rope, allowing the marine arm to swing violently back and forth. The lower end of the arm, the flange end, struck Employee #1 in his right chest and killed him. Upon investigation, it was found that a stud on one of the clips did not have a nut on it and the paint on the clip did not indicate that a nut was ever on the bolt. The remaining clip bolts had very little paint scrapings, indicating that the nuts were never fully torqued either at the factory or upon installation at the refinery. Once any weight was applied to the retaining cable, the fist grip clips could not hold the weight and the wire rope slipped, allowing the marine arm to swing.

Keywords: LONGSHORING, BARGE, STRUCK BY, FLYING OBJECT, WORK RULES, SLIP, OFF LOADING, CHEST, WIRE ROPE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107630030 Occupation Not Listed
2 107630022 Fatality Concussion Occupation not reported
3 107630055 Occupation Not Listed
4 107630048 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.