Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 514679 - EMPLOYEE KILLED IN FALL FROM ELEVATION

Accident Summary Nr: 514679 -- Report ID: 0625700 -- Event Date: 01/10/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11033870401/22/199017310River City Electric Co. Inc.

Abstract: On January 10, 1990, Employee #1, owner of Riverdale Electric Company Incorporated, was working from an elevator bucket on a Reach Aerial Lift (Model Number HD5045, Series Number 6000, Serial Number 4578CC) mounted on a Chevrolet 2.5 ton 1981 model truck. He was changing out some light bulbs in the parking lot which were 40 feet high. He extended nitrogen on the back of the truck and began to rise in the bucket. The bottom was off-center and the truck tipped to the right. The elbow of the extended boom hit a car in the parking lot and propelled Employee #1 from the bucket, which was approximately 30 feet in air. Employee #1 fell between two cars striking his head. He sustained a fractured skull and died due to cardio pulmonary arrest and multiple traumas. Employee #1 was not wearing a safety belt attached to a lanyard.

Keywords: FRACTURE, HEAD, BOOM, SAFETY BELT, NITROGEN, CARDIAC ARREST, SKULL, AUTOMOBILE, BUCKET ELEVATOR, AERIAL LIFT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 110338704 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.