Accident Summary Nr: 511055 - FLASH FIRE AT EXPLOSIVES MANUFACTURING PLANT

Accident Summary Nr: 511055 -- Report ID: 0931600 -- Event Date: 05/19/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
233005805/21/198628990Dela-Tek, Inc.

Abstract: AT 10 AM ON MAY 19, 1986, EMPLOYEES #1 THROUGH #3 WERE USING WATER AND ACETONE TO CLEAN A SIMPSON MULLER-MIXER. THE MIXER CONTAINED LESS THAN 10 POUNDS OF RESIDUE FROM A MAGNESIUM-TEFRON-FLUOREL-ACETONE MIXTURE. THEY WERE LOCATED IN THE PROCESS BUILDING AT A REMOTE LOCATION. A FLASH FIRE OCCURRED, APPARENTLY WHEN FLAMMABLE VAPORS WERE IGNITED BY STATIC ELECTRICITY. THE EMPLOYEE'S SHIFT HAD STARTED AT 7 AM. AT 8 AM, IN ACCORDANCE WITH COMPANY POLICY, THEY BEGAN THE SHUT-DOWN PROCESS BECAUSE OF HIGH WINDS AND 20% HUMIDITY. AT 8:30 THEY WERE ORDERED TO STOP THE BATCH PROCESS AND CLEAN UP. THERE WAS NO MONITORING OF FLAMMABLE VAPORS AT THE PROCESS BUILDING. COMBUSTIBLE MATERIAL WAS USED FOR THE CONSTRUCTION OF THE EMPLOYEE'S WORK PLATFORM AND FOR THE WALLS OF THE PROCESS BUILDING. THE EMPLOYEES WERE GIVEN NO FORMAL TRAINING ON THE HAZARDS OF THE CHEMICALS THEY WERE USING. EMPLOYEE #1 DIED 29 DAYS LATER AND EMPLOYEE #2 DIED 5 DAYS LATER. THEY WERE BURNED OVER 88% OF THEIR BODIES, ESPECIALLY THE FACE, UPPER TRUNK, AND EXTREMITIES, AND EXPERIENCED RENAL FAILURE AND EDEMA OF THE LUNGS. EMPLOYEE #3 ALSO EXPERIENCED EXTENSIVE BURNS BUT SURVIVED, AND WAS RELEASED FROM THE HOSPITAL 2 MONTHS LATER ON AN OUTPATIENT BASIS.

Keywords: BURN, LUNG, FLAMMABLE VAPORS, EXPLOSIVE MIXING, CLEANING, FIRE, TORSO, FACE, UNTRAINED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2330058 Fatality Burn/Scald(Heat) Occupation not reported
2 2330058 Fatality Burn/Scald(Heat) Occupation not reported
3 2330058 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close