Accident Summary Nr: 509745 - Two employees killed in trench cave-in

Accident Summary Nr: 509745 -- Report ID: 1032500 -- Event Date: 05/03/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
10724120005/04/199517940Jack Robinson
Inspection NrDate OpenedSICNAICSEstablishment Name
10724119205/04/199515310John Moore Construction

Abstract: On the morning of May 3, 1995, Employee #1, an excavator, was digging up the sewer line to a single family home that Employee #2 was building on 6 to 7 feet of fill dirt. The line had been installed and covered, but, due to a miscalculation the vent ended up inside the foundation area. Employee #1 was digging up the line in order to move the vent, and was making a trench approximately 12 feet deep by 3 feet wide by 7 feet long. The walls were nearly vertical and not shored. The spoils pile was located on the edge of the trench and the ground was wet due to recent rains. When Employee #1 entered the trench to work on the line, the wall collapsed, trapping him under approximately 3 feet of dirt. Employee #2 jumped into the trench to rescue him and the wall collapsed again, trapping Employee #2 under another 3 feet of dirt. Both men died of asphyxia before they could be rescued. Employees #1 and #2 were sole owners, with no exposed employees.

Keywords: EXCAVATION, ASPHYXIATED, WORK RULES, SHORING, CAVE-IN, CONSTRUCTION, TRENCH, UNSTABLE SOIL, SLOPING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107241200 Fatality Asphyxia Occupation not reported
2 107241192 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.