Abstract: Employee #1 entered a confined space with a lighted torch. The atmosphere was not tested and contained an explosive concentration of propane gas. The propane gas exploded, sending the employee approximately 20 feet in the air, and igniting his clothing. Employee #1 sustained 2nd- and 3rd-degree burns over 70 percent of his body. He died of respiratory arrest two days later. A propane torch had been left on in the space overnight and the flame had gone out, allowing propane to accumulate. Citations were issued.

Keywords: BURN, CLOTHING, CONFINED SPACE, WORK RULES, FIRE, CONSTRUCTION, PROPANE TORCH, TORCH, EXPLOSION, PROPANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107232167 Fatality Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.