Accident Summary Nr: 47846.015 - Employee is caught below deck on a capsized tugboat and drow

Accident Summary Nr: 47846.015 -- Report ID: 0523300 -- Event Date: 07/03/2013
Inspection NrDate OpenedSICNAICSEstablishment Name
917531.01507/10/2013483211Brennan Marine, Inc.

Abstract: At 6:00 a.m. on July 3, 2013, an employee was assisting with towing a barge on the Mississippi River. The employee removed the mooring lines from the lock bollards and the barge captain tried to engage the engines but the engines did not engage, leaving the tugboat with no propulsion capabilities. The tugboat drifted and was swept through a dam lock where it rolled to its port side. The captain and a coworker were in the pilot house cabin and were swept overboard before being rescued. The employee had left the pilot house to go to the deck below and was caught by the water flowing into that level. The employee drowned.

Keywords: Barge, Drown, Drowning, Ship

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 917531.015 22 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.