Accident Summary Nr: 46306.015 - One employee falls from derrick platform and is killed; One

Accident Summary Nr: 46306.015 -- Report ID: 0627100 -- Event Date: 06/11/2013
Inspection NrDate OpenedSICNAICSEstablishment Name
911088.01506/12/2013213112Reliance Well Service, Inc.

Abstract: At 1:00 p.m. on July 11, 2013, Employee #1 was training a coworker on derrickman operations from the derrick floor. Employee #1 and his coworker had tied off to the platform using a full body harnesses and manila ropes. Employee #1 latched a pipe from the edge of the monkey board and lost their balance when standing up from a squatting position. The rope attached to Employee #1's body harness broke and Employee #1 fell approximately 50 feet before hitting Employee #2 who was standing on the rig floor. Employee #1 was killed with head injuries and Employee #2 suffered bruising to the shoulder and collarbone area.

Keywords: Collarbone, Digger/Derrick, Fall, Fall Protection, Head, Oil Well Drilling/Servicing, PPE, Rope, Shoulder

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 911088.015 M Non Hospitalized injury Occupation Not Listed
2 911088.015 28 M Fatality Drillers, earth

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close