Accident Summary Nr: 45166.015 - Employee is struck by chop gate on a silo and is killed

Accident Summary Nr: 45166.015 -- Report ID: 0626300 -- Event Date: 05/06/2013
Inspection NrDate OpenedSICNAICSEstablishment Name
905826.01505/06/2013324121Longview Asphalt, Inc.

Abstract: At 10:08 a.m. on May 6, 2013, two employees opened chop gates on bottom of an overhead silo to clean /chip the hot mix build up at the silo ring. Employee #2 used a chain to wrap around the gate to secure to silo support I-Beam. The employees failed to utilize LOTO procedure by placing pin/wrench in air valve to keep constant air supply to Air Cylinder so that gate would not close. While Employee #1 stood on a 6-foot stepladder which was placed on the bed of the dump truck to perform the work, the hook on the chain and I-beam broke causing the gates to close, striking Employee #1 on the head. Employee #1 was struck by and caught between the chop gates and was killed.

Keywords: Lockout/Tagout, Silo, Struck By

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 905826.015 42 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close