Return to Accident Search Results
Accident Report Detail
Accident Summary Nr: 43784.015 - Employee struck-by excavator's counterweight, is killed
Accident Summary Nr: 43784.015 -- Report ID: 0626600 -- Event Date: 04/22/2013
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 902325.015 | 04/22/2013 | | 237120 | Sunland Construction, Inc. |
Abstract:
At 10:07 a.m. on April 22, 2013, an employee was picking up pieces of wood called skids to set under pipes waiting to be moved into the excavation. Loose skids were in proximity of the excavator, and the employee was walking towards the working excavator and stationary pipe. Employee #1 entered the swing area of a Komatsu PC310LC-10 hydraulic excavator and he couldn't hear the formen and spotter yelling at him to get out of the swing area. Employee #1 was caught between the excavator's counterweight and the staged piping. Employee #1 died at the scene from his injuries. The employee sustained crushing injuries of the chest and shoulder.
Keywords:
Counterbalance, Excavation, Excavator, Pipe
Accident Details
| End Use |
Project Type |
Project Cost |
Stories |
Non-building Height |
Fatality |
| Excavation, landfill |
New project or new addition |
$20,000,000 and over |
0 |
0 |
X |
Employee Details
| Employee # |
Inspection Nr |
Age |
Sex |
Degree of Injury |
Nature of Injury |
Occupation |
| 1 |
902325.015 |
27 |
M |
Fatality |
|
Excavating and loading machine operators |