Accident Summary Nr: 43224.015 - Employee operating an aerial lift is killed

Accident Summary Nr: 43224.015 -- Report ID: 0522500 -- Event Date: 04/12/2013
Inspection NrDate OpenedSICNAICSEstablishment Name
900324.01504/12/2013237310Double Z Construction

Abstract: At 10:00 a.m. on April 12, 2013, a total of eight employees were working at the site during the time when the fatal event took place. Employee #1, a 34 year old male welder, was operating an aerial lift and working directly with Employee #2, a crane operator, during the preparation of removing a 60 foot I-beam used in part to support an overpass/bridge. This was the first I-beam that was removed on this job site. Employee #1 used an oxygen/acetylene torch in order to cut through the I-beam in a 60 foot section and to burn two holes that were spaced approximately 6 feet from the center on one side and 19 feet on the other side of the I-beam, in order for the shackles to be installed as part of the crane's rigging. Employee #1 rigged two 7/8 inch diameter by 16 foot long, mechanically-spliced sling legs from the shackles to the crane's hook. Employee #1 was also tasked to be the designated signalman for Employee #2 to take all commands from during this lift. Employee #1 retracted the telescoping aerial lift in order for Employee #2 to begin his swing of the load. During the crane's operation with the 60 foot long I-beam, the sling leg that was on the side where Employee #1 was positioned in the aerial lift, slid out of the crane's hook, causing one side of the steel I-beam to fall and come in contact with the aerial lift where Employee #1 was located. This caused the basket to almost completely break away from the aerial lift's boom. The aerial lift crashed to the ground below along with Employee #1, resulting in crushing injuries to the employee's back and neck which resulted in his near instantaneous death. Employee #1 had been doing this type of work with this company for approximately six years. There were some weather variables that Employee #1 was required to negotiate, which were the cold air temperature and the muddy soil conditions.

Keywords: Aerial Lift, Back, Boom, Boom Support Cable, Boom Truck, Crane, Crushed, Fall, Fall Protection, Falling Object, Neck, Rigging, Steel Erection
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Bridge Demolition   30 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 900324.015 34 M Fatality Welders and cutters Distance of Fall: 10 feet
Worker Height Above Ground/Floor: 10 feet
Cause: Placing bridge girders and beams
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.