Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 42822.015 - One employee is killed and one injured in oil tanker explosi

Accident Summary Nr: 42822.015 -- Report ID: 0830300 -- Event Date: 03/27/2013
Inspection NrDate OpenedSICNAICSEstablishment Name
898588.01503/28/2013484220Plains Trucking Llc

Abstract: At 3:15 p.m. on March 27, 2013, Employee #1 and #2 were preparing to clean out the inside of a crude oil tanker trailer with a power washer. They were in the first step of the process which was empting the trailer of residual oil when an explosion occurred. The explosion blasted a hole in the roof, throwing Employee #1 through the roof, killing him. He was found on the ground outside of the shop. Employee #2 was found inside the shop with a cut to the forehead and burn injuries. Employee #2 was air-lifted to a local hospital for treatment.

Keywords: Burn, Combustible Liquid, Confined Space, Crude Oil, Explosion, Forehead, Laceration, Oil Tank, Roof, Tank Truck, Trailer

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 898588.015 20 M Hospitalized injury Laborers, except construction
2 898588.015 19 M Fatality Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close