Accident Summary Nr: 361704893 - Employee exposed to chemical in confined space

Accident Summary Nr: 361704893 -- Report ID: 0950627 -- Event Date: 02/08/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
12573989603/20/200273630Timec Company Inc. Dba Welltech Safety

Abstract: At approximately 10:00 p.m. on February 8, 2002, Employee # 1, a contractor employee, was acting as a confined-space attendant monitoring an entrant who was inspecting the interior of an 85-foot-tall processing vessel at a petroleum refinery. A ventilation blower was supplying air through the lower manway, and the air stream was exiting at the upper manway, where Employee #1 was located. She was exposed to an unknown chemical that resulted in acute symptoms including vomiting, coughing, difficulty breathing, edema on her exposed skin, and loss of consciousness. Employee #1 was hospitalized for 5 days in an intensive care unit.

Keywords: RESPIRATORY, UNCONSCIOUSNESS, VENTILATION, CONFINED SPACE, CHEMICAL VESSEL, REFINERY, CHEMICAL, COUGH, VOMIT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125739896 Hospitalized injury Poisoning(Systemic) Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close