Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 311694525 - Two Firefighters Burned in Fire Simulator

Accident Summary Nr: 311694525 -- Report ID: 1054191 -- Event Date: 02/05/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31169452502/08/20089224922160Columbia River Fire And Rescue

Abstract: At approximately 1:00 p.m. on February 5, 2008, Employees #1 and #2 were fire officers for Columbia River Fire and Rescue. In a morning classroom session, fire fighters received training from the WRG Fire Simulator Company, the contractor responsible for design, construction and instruction for the simulator. Following the classroom session, the fire fighters began to work with the live fire props. There were two burn rooms, one on the first floor and one on the second floor. Use of the live fire props began in the first floor burn room. There were four to six fires suppressed by the officers in the late morning. After lunch, the group moved upstairs to the second floor burn room. There were three fires ignited in the second floor burn room. Employee #1 and #2 were burned after the third fire. It was determined that the amount of fuel injected into the room exceeded the ability of the ventilation system to control it. Hose stream pushed unburned propane to the back of the room. After the fire was thought to be extinguished and the hose lines were shut down, the unburned propane ignited, rolled forward and flashed out the door. Employees #1 and #2 were standing straight out from the door, approximately 20 ft from the burn room in the staging room. They were treated at Emmanual Hospital for second-degree burns to their faces and hands.

Keywords: BURN, FIREFIGHTER, FIRE, PROPANE, FACE, HAND

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 311694525 Non Hospitalized injury Burn/Scald(Heat) Firefighting occupations
2 311694525 Non Hospitalized injury Burn/Scald(Heat) Firefighting occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close