Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 301127254 - Employee Is Burned in Fire While Cleaning Pipes with Diesel

Accident Summary Nr: 301127254 -- Report ID: 0950663 -- Event Date: 01/15/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
30112725401/15/20072911324110Chevron Usa,Inc. Dba Chevron Products Company

Abstract: On January 15, 2007, Employee #1 was working with two coworkers to start a steam-driven back up pump for crude circulation. Employee #1 was starting the pump to circulate diesel through the system. Employee #1 placed the pump in the proper configuration and then proceeded to open the steam valve to start the pump. Within seconds of starting the pump, a "pop" sound was heard and a stream of diesel from adjacent piping ensued. The stream of diesel was approximately 15 ft high. Employee #1 and the two helpers were soaked in diesel. All three employees ran in different direction to get away from the pressurized diesel stream. The diesel caught fire and burned for hours. The causal factor for the accident was a missing seat in the 4-in. gate valve. Sulfur containing material migrated past this Valve. The pipe beyond the Valve was not meant for a sulfur containing material and corroded to exhaustion. Employee #1 sustained second-degree burns to the back of his neck as a result of a release of diesel and its subsequent ignition. Employee #1 was hospitalized.

Keywords: BURN, CLEANING, FIRE, STEAM, CORROSION, VALVE, PIPE, REFINERY

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 301127254 Hospitalized injury Burn/Scald(Heat) Miscellaneous plant and system operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close