Accident Summary Nr: 300833696 - Employee Is Nearly Asphyxiated in Trench Cave-In

Accident Summary Nr: 300833696 -- Report ID: 0950643 -- Event Date: 04/11/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
30083369604/11/20061623237110Vci Telecom Dba Vci Construction

Abstract: At approximately 1:03 p.m. on April 11, 2006, Employee #1 was working for VCI Telecom, Inc., DBA VCI Construction, a general utility construction company engaged in the construction and repair of water, power, and other utility lines. He had been working for company since December 2004 as a laborer. He was working near other onsite VCI Telecom, Inc., DBA VCI Construction employees, including a supervisor-carpenter. He was placing an underground pipe for the installation of a 5-inch conduit from a manhole to a pole in the City of Oxnard, CA, when part of the trench, not properly shored, caved in on him. He was nearly asphyxiated, and he was transported to St. Johns Regional Medical Center, where he was hospitalized for treatment. He was released on April 18, 2006. Interviews were conducted of Employee #1, his supervisor, and other onsite coworkers. The investigation concluded that violation of CCR Title 8 Section 1541.1(a)(1) was the cause of this accident. At the time of accident, the employer did not follow Manufacturer's Tabulated data for providing adequate protective system for an employee working in a 6- to 7-foot deep excavation. As a result, the Division issued a serious accident-related citation to the employer, CCR Title 8 Section 1541.1(a)(1).

Keywords: CHEST, ASPHYXIATED, COMMUNICATION CABLE, CONDUIT, WORK RULES, TRENCH, CAVE-IN
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Excavation, landfill Other Under $50,000 6

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 300833696 Hospitalized injury Asphyxia Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause: Trench collapse

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.