Accident Summary Nr: 29695.015 - Employee Is Struck By Falling Dump Truck Tailgate, Suffers H

Accident Summary Nr: 29695.015 -- Report ID: 0112000 -- Event Date: 09/24/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
655898.01509/25/2012238990Galasso Materials, Llc

Abstract: At approximately 4:05 p.m. on September 24, 2012, Employee #1 was cleaning the tailgate of a dump truck. The tailgate was propped open with a wooden stake. As he cleaned the tailgate, the wooden stake broke, which caused the tailgate to fall. The tailgate struck him on his head, caused a severe laceration and blunt force head trauma. Employee #1 was transported to a hospital, where he later died.

Keywords: Caught In, Crushing, Falling Object, Material Handling, Struck By
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other heavy construction Alteration or rehabilitation   X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 655898.015 57 M Fatality Truck drivers, heavy Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Paving
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.