Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 27155.015 - Employee Is Burned in Chemical Fire

Accident Summary Nr: 27155.015 -- Report ID: 0625700 -- Event Date: 08/24/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
610478.01508/27/2012325199Golden Leaf Energy, Inc.

Abstract: At 9:00 p.m. on August 24, 2012, an employee was stirring 180 gallon mixture of Sulfuric Acid (30 gallons) and Methanol (150 gallons) with a piece of PVC pipe while in a cage tote. As the employee stirred the chemicals, a static electricity charge built up in the cage tote and the chemicals exploded causing a fire. The employees entire body was burned in the fire. The employee was killed

Keywords: Chemical Burn, Chemical Reaction, Explosion, Fire, Methyl Alcohol, Sulfuric Acid

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 610478.015 37 M Fatality Chemical engineers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.