Accident Summary Nr: 23415.015 - Three Employees Receives Burns And One Employee Is Killed Wh

Accident Summary Nr: 23415.015 -- Report ID: 0524530 -- Event Date: 07/24/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
540479.01507/25/2012213111Bankston Creek Land Trust

Abstract: At approximately 11:00 a.m. on July 24, 2012, Employee #1, #2, #3 and #4, a crew, were conducting swabbing operations on an oil well site. The swabbing operation involved the removal of diesel fuel, crude oil and water from another well. A tank had been delivered from another site, which a swabbing operation was conducted. The tank was a metal vessel that was approximately 17 ft high by 12 ft in diameter. For the swabbing operation on this site, the crew filled the tank with salt water in preparation of a fracking operation. The crew noted that a leak was present on the bottom of the tank and proceeded to drain the tank to repair the leak. A welder proceeded to repair the bottom side of the metal tank. The tank was sitting on an angle on the back of a delivery flatbed truck. Employee #2, a welder, had finished welding work on the swabbing tank when all of the employees allegedly heard a hissing noise from the tank. After hearing the hissing noise, the crew walked away from the tank. An explosion occurred a few seconds later, which enveloped four of the employees standing to the south of the tank. The flash fire ignited the tank wheels on fire, but quickly burned out. Employee #1 received second and third-degree burns to the arm and head. Employee #2 received second and third-degree burns to 95 percent of the body, and later died due to injuries received. Employee #3 received second and third-degree burns to the arms and face. Employee #4 received burns to the arms. Employee #1, #3 and #4 were transported to the medical center burn unit, where they underwent burn treatment and were then hospitalized.

Keywords: Burn, Combustible Liquid, Explosion, Oil Well Drilling/Servicing, Pressure Vessel

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 540479.015 35 M Hospitalized injury Drillers, oil well
2 540479.015 36 M Fatality Drillers, oil well
3 540479.015 35 M Hospitalized injury Drillers, oil well
4 540479.015 28 M Non Hospitalized injury Drillers, oil well

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.