Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 23255.015 - Employee's Foot Is Struck By Falling Object And Is Amputated

Accident Summary Nr: 23255.015 -- Report ID: 0521700 -- Event Date: 04/05/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
329922.01504/05/2012238120Imperial Construction Associates, Inc.

Abstract: At approximately 12:00 p.m. on April 5, 2012, Employee #1 and a crew were installing steel plates to create a wall. The steel plates were approximately 17.5 ft in height. Employee #1 welded a lifting eye to the steel plate and rigged the plate to a carry deck crane. As the plate was being put into position, the lifting eye weld broke free from the plate. Employee #1 was walking with a piece of steel and the plate landed on his foot and amputated it. An investigation determined that the weld did not penetrate the two pieces of steel. Employee #1 was transported to a medical center, where he underwent medical procedures for the foot amputation and was then hospitalized.

Keywords: Amputated, Broken Weld, Falling Object, Foot, Steel, Steel Plate, Struck By, Suspended Load
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Manufacturing plant New project or new addition $500,000 to $1,000,000 2

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 329922.015 26 M Hospitalized injury Strctural Iron /& Steel Worker Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Erecting structural steel
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.