Accident Summary Nr: 202674594 - Employee Amputates Finger When Caught in Gluing Press

Accident Summary Nr: 202674594 -- Report ID: 0950621 -- Event Date: 01/24/2013
Inspection NrDate OpenedSICNAICSEstablishment Name
31652100402/12/20132431321918Sierra Pacific Industries

Abstract: On January 24, 2013, Employee #1, an operator, was assisting another operator with an industrial lumber gluing press. The operator of this machine would stack lumber on to the conveyor chains then send them to the opening of the gluing press. When the gluing press was ready to accept the next load, the chains dropped below the deck then a carriage pushed the lumber into the press. At the time of the accident, there was a crash. It was explained to the inspector a crash is when the strips of lumber to be glued come down the chain conveyor then either falls over or a miss feed happens because the width is too wide to enter the press. The assistant, Employee #1, was working on the opposite side of the machine and was removing boards and restacking the lumber so it will feed correctly into the glue press. Even though the operator hit the emergency stop on the machine, it does not stop the air system which would raises and lower the chain conveyor assemblies nor does it disable the photo eyes which control this system. As the employee reached in to remove a piece of lumber, the lumber tripped a photo eye which commanded the chain assembly to rise above the deck to feed more lumber, amputating Employee #1's right pinky finger as it was pinched between the chain assembly and the machines deck. Employee #1 was taken to Saint Elizabeth's Hospital, where he was treated for an amputation of the pinky finger and released.

Keywords: CHAIN, AMPUTATED, GLUE, FINGER, CAUGHT BETWEEN, LUMBER, CONVEYOR, NIP POINT, PRESS

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 316521004 Non Hospitalized injury Amputation Miscellaneous woodworking machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close