Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202626719 - An Employee Is Hit as Baler Door Blows Open, Later Dies

Accident Summary Nr: 202626719 -- Report ID: 0352430 -- Event Date: 01/25/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
31622112601/25/20122752323110S&S Graphics Acquisition Llc Dba Westland Printer

Abstract: On January 25, 2012, Employee#1 walked by baler when four fingers/latches on baler door blew open. Employee#1 was struck in the chest and legs knocking her backwards. A hand packer had operated baler less than 15 minutes when door blew. Both Employee#1 and the hand packer worked for S&S Graphics Acquisition Llc Dba Westland Printer. Employee#1 was taken to hospital, later died.

Keywords: SAFETY LATCH, SHEAR, BALER DOOR, LOSS OF BLOOD, PRINTING, HYDRAULIC TOOL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 316221126 Fatality Other Hand packers and packagers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.