Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202614384 - Roofer Fractures Arm in Shingle Delivery Conveyer Belt Drum

Accident Summary Nr: 202614384 -- Report ID: 1054112 -- Event Date: 04/26/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
31642403504/30/20122952324122Herbert Malarkey Roofing Co

Abstract: On April 26, 2012, an employee was working for a roofing company. Bundles of shingles were being conveyed on either a belt or a rollcase. The narrative was not clear on that point. He reached into a drum at the end of the outfeed conveyor at which bundles of shingles were delivered. Either his arm was caught in the drum or it was caught be a roller in the rollcase. He sustained a fracture in his lower arm.

Keywords: FRACTURE, ROTATING PARTS, ROOF, CAUGHT BY, CONSTRUCTION, ROLLER CONVEYOR, ROLLER--MACH/PART, ROOFER, ARM, CONVEYOR BELT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 316424035 Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.