Accident Summary Nr: 202588745 - Employee Is Run over by Dump Truck and Killed

Accident Summary Nr: 202588745 -- Report ID: 0950614 -- Event Date: 08/27/2013
Inspection NrDate OpenedSICNAICSEstablishment Name
31720155608/27/20131542236220Robert A. Bothman, Inc.

Abstract: At approximately 1:45 p.m. on August 27, 2013, Employee #1, with Robert A. Bothman, Inc., was working behind a parked three-axle dump truck. He was working with a coworker and an independent contractor and was repairing the asphalt pavement. The truck reportedly was parked on a pathway near the top of a small hill that connected the track and field area to the main campus of the school, where they were working. The driver of the truck reported that he: parked the truck; set the brake; exited the vehicle; and, was at the rear of the truck, where the group of workers was repairing the asphalt pavement. Then, the truck began to roll backwards down the hill. Employee #1 was unable to get out of the path of the truck and was struck by the vehicle. All of the witnesses reported that Employee #1 was obviously dead from the injuries he sustained. Based upon the evidence gathered during the investigation, the employer did not ensure that the vehicle was under positive control at all times, by ensuring that the parking brake was set and the wheels were chocked or otherwise effectively prevented from movement by effective mechanical means.

Keywords: CHOCK, BRAKE, ROLL-OVER, CONSTRUCTION, DRIVER, DUMP TRUCK, STRUCK BY, LOST CONTROL, MOTOR VEHICLE, ASPHALT
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building Alteration or rehabilitation $500,000 to $1,000,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 317201556 Fatality Other Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Backfilling and compacting
Fatality Cause: Crushed/run-over by highway vehicle

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.