Accident Summary Nr: 202587713 - Iron Worker Fractures Hip in Fall on Bridge

Accident Summary Nr: 202587713 -- Report ID: 0950614 -- Event Date: 07/23/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
31531884007/30/20121622237310American Bridge/Fluor Enterprises Inc Jv

Abstract: Sometime before approximately 8:30 a.m. on July 23, 2012, an employee was working as an iron worker. He was working at a construction venture being run jointly by American Bridge Company and Fluor Enterprises, Inc. He had been in the trade for approximately 11 to 12 years. The project was the replacement of the east span of the San Francisco - Oakland Bay Bridge. The project's staging area was a large yard covering several acres and containing mobile office buildings, located in Oakland, CA. The actual bridge work extended over San Francisco Bay. The incident occurred inside horizontal open box girder # 12, located mid-span on the bridge. The employee and his coworkers were removing pieces of horizontal angle iron used to mechanically hold the horizontal sections of the open box girder sections in place until they could be welded together. At the time of the incident, the employee was removing one of the angle iron plates. As he was standing on a work platform from which he was working, his left foot slipped. He fell onto a structural member of the work platform. His left hip struck the structural member, and he sustained a fracture of at least one and possibly both of his hips. The employee was taken to a local hospital, where he was treated for his injuries for more than 24 hours. At approximately 8:30 a.m. that day, the Cal/OSHA DOSH Oakland District office received a report of this serious workplace health and safety injury from the Oakland Fire Department via telephone. At approximately 2:10 p.m. on July 30, 2012, the Division arrived at the place of employment, which was the east landing of the San Francisco - Oakland Bay Bridge renovation project, in Oakland, CA, and conducted an opening conference with management.

Keywords: FRACTURE, GIRDER, IRON WORKER, SLIP, CONSTRUCTION, STEEL ERECTION, FALL, BRIDGE, WORK PLATFORM, HIP
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Bridge New project or new addition $20,000,000 and over 525

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 315318840 Hospitalized injury Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 2 feet
Cause: Placing bridge girders and beams
Fatality Cause: Fall from/with scaffold

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.