Accident Report Detail

Accident Summary Nr: 202573671 - Employee Is Injured in Fall from Work Platform

Accident Summary Nr: 202573671 -- Report ID: 0352410 -- Event Date: 01/09/2009
Inspection NrDate OpenedSICNAICSEstablishment Name
31273725701/09/20091542236220Pe Moore & Sons Construction Llc

Abstract: On January 9, 2009, Employee #1 and a coworker were working from a scaffolding platform to install siding. The scaffolding platform was located approximately five feet above the ground and was supported by an all-terrain forklift. In addition, the scaffold platform measured approximately 6-feet wide by 12-feet long, and was protected by a metal tube guardrail system, where the top rail was located approximately 40.5 inches above the metal floor of the scaffold platform and the midrail approximately 21 inches above the metal floor of the scaffold platform. Within the guardrail system the was an opening for access/egress of the scaffold platform, which provided an approximate 31 inch opening that was guarded by two chains with snap hooks to close off the opening. While Employee #1 and his coworker finished working for the day and were cleaning up, their supervisor had the platform lowered and removed the chains guarding the access/egress opening. As the platform was lowered, an airline had become caught on something. The supervisor instructed Employee #1 move the airline. Employee #1 removed the airline and then stepped backwards, unaware that the access/egress chains had been removed. He fell from the platform through the opening in the guardrail system and struck his head against a section of brick that projected from the building, approximately 5 inches, and landed on his right shoulder. Employee #1 was taken by helicopter to the University of Maryland Hospital, where he was seen by specialists in their Shock Trauma Unit and treated for a concussion, bruised right shoulder, and bruised upper right arm.

Keywords: FRACTURE, HEAD, SAFETY LATCH, GUARDRAIL, SHOULDER, STRUCK AGAINST, FALL, FALL PROTECTION, CONCUSSION, WORK PLATFORM
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $1,000,000 to $5,000,000 3 36

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 312737257 Non Hospitalized injury Concussion Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 5 feet
Cause: Installing metal siding
Fatality Cause: Fall from/with scaffold

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.