Accident Summary Nr: 202544912 -- Report ID: 0950641 -- Event Date: 10/29/2012
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 314863978 | 11/06/2012 | 1794 | 238910 | W A Rasic Construction Co Inc |
Abstract:
At approximately 2:30 a.m. on October 29, 2012, Employee #1, employed as a laborer by a construction company, was performing excavation work at Los Angeles International Airport. He had been working there for a few months, with duties that included removing a metal plate to expose a trench beneath. He was performing this regularly assigned task, using an excavator to move the metal plates, and in close proximity to Coworkers #1 and #2. The plate was rigged with a sling and attached with a hook. Employee #1 was guiding the plate with his hand. The sling slipped out of the hook, whereupon the plate fell and landed on Employee #1's hand. He was transported to UCLA Ronald Reagan Hospital, where he was hospitalized and treated for a crushed hand. The employer's Safety Director notified the Cal/OSHA Division on October 29, 2012. The investigation, which began November 6, 2012, included interviews with Employee #1 and Coworkers #1 and #2. The investigation concluded that there was a violation for not keeping employees clear of loads about to be lifted and suspended loads. The employer also used a hook that was not designed to work with the type of sling that was used to lift the plate. The Division issued a serious accident related citation for T8CCR 1593(n).
Keywords:
EXCAVATION, COVER, PANEL, SUSPENDED LOAD, CONSTRUCTION, TRENCH, METAL SHEET, CRUSHED, SLING, HAND
Accident Details
| End Use |
Project Type |
Project Cost |
Stories |
Non-building Height |
Fatality |
| Commercial building |
New project or new addition |
$500,000 to $1,000,000 |
3 |
|
|
Employee Details
| Employee # |
Inspection Nr |
Age |
Sex |
Degree of Injury |
Nature of Injury |
Occupation |
| 1 |
314863978 |
|
|
Hospitalized injury |
Other |
Construction laborers |